Honeywell FC-Tpsu-2430 FC-PSU-240516 FC-Tshart-1620m FC-Bkm-0001 FC-Tsdo-0824 FC-Sai-1620 DC/DC Converter Safety Manager System Module
Contact Supplier
Product Highlights
- 12 Months Warranty: Comprehensive 12-month warranty coverage for all mechanical and electrical defects.
- In Stock Availability: Immediate shipment available from Xiamen, Fujian, China with no lead time delay.
- Global Shipping Options: Fast delivery via DHL, UPS, FedEx, EMS, and other international carriers.
- OEM and ODM Services: Flexible customization options available for original equipment manufacturing needs.
- 100% New Condition: All units are brand new with original packaging and verified quality.
- HART Interface Support: Integrated HART interface for advanced communication with field devices.
- Safety Manager System: Designed for critical safety applications with redundant power and input capabilities.
- DIN Rail Mounting: Standard DIN EN rail compatibility for easy installation in control panels.
Product Attributes
- Customization
- Available
- Task
- Program
- Structure
- Combination
- Model NO.
- FC-TPSU-2430
- Function
- Automatic Control
- Condition
- New
- Customized
- Non-Customized
- Product Type
- DC/DC Converter
- Product Serie
- Safety Manager System
- Manufacturer
- Honeywell
- Quality
- 100 % New with Original Package
- Warranty
- 12 Months
- Lead Time
- in Stock
- Shipping From
- Xiamen, Fujian, China
- Shipment Method
- DHL\UPS\FedEx\EMS\Others
- Package Weight
- 2.5kg
- Net Weight
- 0.44kg
- Transport Package
- Standard Package
- Specification
- 15x7x5.8cm
- Origin
- USA
- HS Code
- 8537101190
- Package Size
- 13.50cm * 24.00cm * 24.50cm
- Package Gross Weight
- 2.000kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of Honeywell FC-Tpsu-2430 FC-PSU-240516 FC-Tshart-1620m FC-Bkm-0001 FC-Tsdo-0824 FC-Sai-1620 DC/DC Converter Safety Manager System Module
Find Similar Products
Product Description
FC-TPSU-2430, FC-PSU-240516, and FC-TSHART-1620M belong to the Honeywell Safety Manager hardware family but serve different layers of the system. FC-TPSU-2430 is a 24 VDC to 30 VDC converter for compatible field termination assemblies, FC-PSU-240516 is the controller-chassis 24/5 VDC power supply unit, and FC-TSHART-1620M is a sixteen-channel safe analog-input field termination assembly with a HART interface.
The other references cover controller backup and key-switch functions, digital-output field termination, and high-density analog input processing. They are complementary Safety Manager components, not interchangeable modules. Always match the complete catalog number, coating/version marking, chassis or FTA location, system interconnection cable, Safety Manager release and field-signal design before ordering.
Six-Reference Function Map
| Full Reference | Verified Product Role | Main System Location | Critical Ordering Check |
| FC-TPSU-2430 | 24 VDC to 30 VDC / 1 A converter | DIN-rail FTA power architecture | Confirm converter version, 30 VDC load, redundancy arrangement and target FTA |
| FC-PSU-240516 | Controller power supply unit, 24/5 VDC, 16 A class | Predetermined PSU slot in the controller chassis | Confirm chassis, PSU version, local/redundant 5 V load and existing module label |
| FC-TSHART-1620M | Safe 0(4)-20 mA analog-input FTA with HART interface, 16 channels | DIN rail between field transmitters and SAI-1620m | Confirm HART multiplexer, passive/active loop design, external 30 VDC power and SICC cable |
| FC-BKM-0001 | Battery and Key switch Module | Dedicated BKM position in controller chassis | Confirm version, battery state, key-switch state and controller maintenance procedure |
| FC-TSDO-0824 | Safe digital-output FTA, 24 VDC, 8 channels | DIN rail between SDO-0824 module and field wiring | Confirm it is TSDO-0824, not TSDO-0824C, plus SICC cable and connected output-module rating |
| FC-SAI-1620 | Title reference requiring nameplate confirmation | Analog-input module position | Current Honeywell reference identifies FC-SAI-1620m; send a label photo before applying SAI-1620m data |
TPSU-2430 24 Vdc to 30 Vdc / 1 A converter
Input
Nominal input voltage: 24 Vdc
Input voltage range: 18-36 Vdc
Inrush current: ≤ 4 A
Output
Output voltage: 30 Vdc ± 0.25 V
Output current: 1 A, short-circuit proof
Short-circuit current: < 3.3 A
Ripple (0-30 MHz): < 0.1 Vrms
Regulation: < 1 % (load + line)
Transient response: class C per NFC42801C
Power-on overshoot: output < 31 V
Overvoltage protection: 31 V
Long-term stability (after 30 min operation): < 0.3 %
Efficiency: > 75 %
Switching frequency: > 25 kHz
Physical
Module dimensions: 150 × 70 × 62.3 mm (5.91 × 2.76 × 2.45 in)
DIN EN rails: TS32 / TS35 × 7.5
Used rail length: 151 mm (5.94 in)
Description
Field termination assembly module TSHART-1620m is the interface between field components (sensors, etc.) and the safe high-density analog input module SAI-1620m in Safety Manager. The FTA provides HART interface. It can be used for interfacing signals from Class I, Division 2 Hazardous Locations.
The TSHART-1620m module has sixteen analog input channels, which may be used for both safety-related and non-safety-related applications. These sixteen channels (separated into two groups of eight channels with common 0 V) are connected via a system interconnection cable (SICC-0001/Lx), which is plugged into the SIC connector on the FTA module, and connects to a (redundant pair of) SAI-1620m module(s).
The FTA module has a universal snap-in provision for standard DIN EN rails, and screw terminals for connection of power supply, ground and field wiring.
Analog-Loop Ordering Check
- Confirm whether each transmitter is active or passive.
- Confirm the exact FC-TPSU-2430 and FC-TSHART-1620M versions used for external 30 VDC power.
- Record the SICC cable catalog number and length.
- Identify the HART multiplexer manufacturer and interface cable if HART access is required.
- Confirm the installed input-module nameplate, especially the final m in SAI-1620m.
- For safety-related passive loops, verify that the Safety Manager application monitors the external-power readback as required by the Honeywell architecture.
The BKM-0001 module contains non-rechargeable (lithium) batteries that supply the back-up power to maintain the diagnostic messages and the real time clock on the QPP modules, in case of a power outage.
As the batteries are not recharged, the used back-up time is accumulating. The total back-up time of the lithium cells is approximately 3 months.
If the system is switched off for a longer period (and during transport), the batteries can be switched off with the battery switch on the module.
It is recommended to replace the batteries every five years and after every substantial discharge period.
Replacing the batteries requires no special tools.
The side plate of the BKM-0001 module has an opening to enable battery replacement and battery-switch operation.
BKM Maintenance Warning
The module can be placed or removed while the system is running without interrupting the application program, but removal always clears all active forces. Put the Force Enable key switch in OFF before extraction and follow the approved Safety Manager maintenance procedure. Do not use the Reset or Force Enable keys as ordinary operating controls.
Installation, Diagnostics & Replacement
Pre-Replacement Checklist
- Record the complete FC/FS model, version marking and coating designation from the front label.
- Identify whether the part is a controller-chassis module, I/O card or DIN-rail FTA before selecting a replacement.
- Save the controller diagnostic messages, module type and timestamp before disturbing hardware.
- Isolate field and controller power according to the site safety procedure; verify all external loop supplies separately.
- Label every SICC cable, HART cable, terminal and 24/30 VDC feed before removal.
- Do not insert an FTA in a controller chassis slot or apply backplane-module data to a DIN-rail FTA.
- After installation, verify status LEDs, diagnostics, channel behavior, external-power readback and configured redundancy before returning the safety function to service.
| Symptom | Relevant Reference | Verification Before Ordering a Spare |
| No regulated 30 VDC at the FTA supply | FC-TPSU-2430 | Check 18-36 VDC input, 3.15 A slow fuse, overload/short circuit, output LED and readback relay |
| Controller PSU status LED is red | FC-PSU-240516 | Check 24 VDC input range, 5 V load, chassis connection and redundant PSU condition |
| Passive analog loops lose process data | FC-TSHART-1620M / FC-TPSU-2430 | Check both external power feeds, group fuses, common 0 V and Safety Manager external-voltage readback |
| HART access is unavailable but analog value remains | FC-TSHART-1620M | Check the specified HART multiplexer, interface connector/cable and common reference; do not alter the safety loop blindly |
| One or more analog channels drift or fail self-test | FC-SAI-1620m path | Check the exact input-module suffix, FTA conversion resistance, cable, channel mapping and diagnostic message |
| Digital load does not energize | FC-TSDO-0824 | Check the connected SDO-0824 module, SICC cable, field supply, output-module rating and terminal wiring |
| BKM status LED remains red | FC-BKM-0001 | Check battery switch position, battery voltage, fuse/diagnostic message and accumulated backup history |
| Forces disappear after BKM service | FC-BKM-0001 | Removal always clears forces; restore only through the approved, authorized forcing procedure |
Compatibility Disclaimer
Safety integrity is a property of the complete approved Safety Manager configuration, not of a spare part considered alone. No claim is made that a different coating version, base model, m suffix, FTA, SICC cable, HART multiplexer or Safety Manager release can be substituted without engineering review.
Moore Automation supplies original new components of PLC, DCS and TSI system from top-tier manufacturers, including A-BB, A-B, Siemens, Honeywell, GE Fanuc, Yokogawa, Triconex, and more. With tens of thousands of parts in stock, we serve clients in over 50 countries, delivering high-quality automation components with fast, reliable shipping.
If you have any need or inquiries about Honeywell or other related series like
Honeywell Experion PKSHoneywell TDC 3000
Honeywell Safety Manager
Honeywell FSC (Fail Safe Controller)
Pls contact us freely!
| TX 5741 | XD26 | C1127-8PLTEP |
| SGDH-04AE | V1000 71000AEP0M0 | SMARTPACK2 242100.601 |
| TA200DU-90 1SAZ421201R1001 | CLR96 946040 | TC806B1076 |
| H7080B2103 | 3RU2146-4HB0 | VM-114H 2XINPUT |
| STBPDT3100K | E31051.5/A004-9/1.0/4.5/8.7 | T-ASH-G2-100 |
| NQ2P10R-52ZSIEI | PW482-10 | GE 312 |
| LBB1856/00 LBB1957/00 | CU230P-2BT 6SL3243-6BB30-1HA3 | effector200 OG5121 |
| EDB14020 | PN:78-2835-01 | LTE-ANTM2-SMA-D |
| IC693MDL940E | YR40.241 | DO561 / 1TNE968902R2201 |
| 50154429-001FRE | PTL-86-461 | F124x04 07400030 |
| AR-133 | PC-301 | DPI-39 |
| 9150/20-11-10 | FS5850-12-05 | SB-RLY12C10A-DN |
| Allen Bradley 1747-L532 | Z5003 | 8102-500 |
| PG4312 | GU8450SS | PTSRB0101V3 |
| TU516-H / 1SAP215000R0001 | 8/24-0.5 203000001 | SFP-H10GB-CU3M 37-0961-03 |
| MU306A 451730 | PTXE6A-M | 2GB |
| BMXDDI3202K | CM7031 | MX-P25-D016 |
| TXM1.8X | VC180 | 03900 |
| CP-168U RS-232 | DRC410F | XFL523 |
| 800-001-0000 | 311025A | KHA6-SH-Ex1 |
Why does the FC-SAI-1620 model require a label photo?
The current Honeywell Hardware Reference identifies the safe high-density analog input type as FC-SAI-1620m. Because the title omits the final m, the installed nameplate must be checked before the 16-channel SAI-1620m technical data or compatibility is applied.
What is the difference between FC-TPSU-2430 and FC-PSU-240516?
FC-TPSU-2430 converts 24 VDC to regulated 30 VDC for compatible FTA and transmitter-loop power arrangements. FC-PSU-240516 is a controller-chassis module that converts 24 VDC to local and redundant 5 VDC rails. They have different outputs, mounting and system roles.
Is FC-TPSU-2430 always required with FC-TSHART-1620M?
Not always. Honeywell states that no external power is required when all inputs are active transmitters. Passive-transmitter loops require guaranteed external power, and FC-TPSU-2430 may be used in a monitored or redundant 30 VDC arrangement. Confirm the actual loop design.
Can FC-TSHART-1620M operate without the SAI input module?
It is a field termination assembly, not the final A/D input module. Its converted signals are intended for SAI-1620m through the correct SICC cable and Safety Manager configuration.
Does FC-TSHART-1620M support every HART multiplexer?
No universal compatibility is claimed. The Honeywell reference describes specific MTL and P-epperl+Fuchs multiplexer/cable solutions. Send the installed multiplexer and cable references before ordering.
Is 1.5 A per channel the usable output rating of FC-TSDO-0824?
It is the published maximum continuous-current boundary of the FTA. Honeywell explicitly states that the actual maximum current is defined by the connected output module, so both the SDO module and the field load must be checked.
Can FC-BKM-0001 be removed while Safety Manager is running?
Honeywell permits placement or removal without interrupting the application program, but removal always clears all forces. The Force Enable switch must be OFF, and the action must follow the site's authorized safety maintenance procedure.
When should the FC-BKM-0001 batteries be replaced?
Honeywell recommends every five years and after substantial discharge. Also review the accumulated backup time, battery-switch position and BKM diagnostics rather than relying only on calendar age.
What information is needed for an accurate quotation?
Send complete front and side label photos, FC/FS type and version, Safety Manager release, chassis or FTA position, SICC and HART cable references, quantity and destination. For analog loops, include whether transmitters are active or passive.
About the Supplier
This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR257476". Items marked "" are certified.
Company Profile
As a leading global supplier of industrial automation and control equipment, Moore Automation has achieved steady growth over the past two decades thanks to its dedicated team, unwavering commitment, and continuous efforts.
Since its founding in 2003, Moore Automation has continuously expanded its product portfolio and customer base. The company has been repeatedly recognized as a trusted and reliable supplier, reflecting its sustained growth and strong reputation in the industry. Today, Moore Automation offers one of the industry's most comprehensive portfolios of industrial automation products, including programmable logic controllers (PLCs), human-machine interfaces (HMIs), distributed control systems (DCS), panel controllers, industrial PCS, and variable frequency drives (VFDs).
With over two decades of experience serving numerous large industrial customers, Moore Automation remains committed to its clear mission: To provide high-quality automation components that are affordable, reliable, and cost-effective. The company has grown into a global enterprise, supporting customers across a wide range of industries worldwide.
From its inception, Moore Automation has adhered to its core principles-quality first, reliable performance, and excellent customer service. With the mission of "helping global production continue, " Moore Automation creates value through a professional team of over 50 employees and an outstanding track record. Moore Automation is built on trust, integrity, and a steadfast commitment to customer satisfaction, ensuring that every product meets high-quality standards and is delivered quickly. The company understands that ensuring smooth industrial operations is crucial to its customers' success.
As a trusted partner to many of the world's leading manufacturers and system integrators, Moore Automation provides both new and discontinued components to help extend the lifespan of existing systems while reducing production waste and material consumption. This model contributes to building a more sustainable industrial future.
Today, Moore Automation's customers are located in more than 120 countries and regions, and the company is well-prepared for continued global growth. The company is proud of its long-standing partnerships and will continue to move forward, upholding its core values.
About Our Factory & Business Background
-
Business Type
- Trading Company
- Address
- Xiamen, Fujian, China
-
Plant Area
- 372.56 square meters
-
Number of Employees
- 54
-
Registered Capital
- 1,680,000 RMB
-
Terms of Payment
- T/T
-
International Commercial Terms(Incoterms)
- EXW
-
Average Lead Time
-
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays -
Nearest Port
- Xiamen Port
-
Minimum Order Quantity
- 1 Piece
-
Supply Chain Partners
- 200
Our Production Capability & Technical Expertise
-
Main Products
- PLC Module, Dcs Module, Controller, Tsi Spare Parts, Sensor, Turbine Card, HMI, Power Supply Module, CPU Module, Processor
-
Customization Options
- Flexible customization
-
ODM Service Available
- Yes
-
OEM Service Available
- Yes
-
R&D Engineers
- 1 people
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2020-04-08
-
Export Year
- 5 Years
-
Main Markets
- North America, South America, Europe, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
-
Repeat Buyers Choice
- 50%~80%
-
Number of Foreign Trading Staff
- 44
-
Overseas Agent/Branch
- No
-
New Products Launched in Last year
- No
Our Certifications, Standards & Industry Recognition
-
Cooperated with Fortune 500
- No
FAQ
- Why does the FC-SAI-1620 model require a label photo?
- The current Honeywell Hardware Reference identifies the safe high-density analog input type as FC-SAI-1620m. Because the title omits the final m, the installed nameplate must be checked before the 16-channel SAI-1620m technical data or compatibility is applied.
- What is the difference between FC-TPSU-2430 and FC-PSU-240516?
- FC-TPSU-2430 converts 24 VDC to regulated 30 VDC for compatible FTA and transmitter-loop power arrangements. FC-PSU-240516 is a controller-chassis module that converts 24 VDC to local and redundant 5 VDC rails. They have different outputs, mounting and system roles.
- Is FC-TPSU-2430 always required with FC-TSHART-1620M?
- Not always. Honeywell states that no external power is required when all inputs are active transmitters. Passive-transmitter loops require guaranteed external power, and FC-TPSU-2430 may be used in a monitored or redundant 30 VDC arrangement. Confirm the actual loop design.
- Can FC-TSHART-1620M operate without the SAI input module?
- It is a field termination assembly, not the final A/D input module. Its converted signals are intended for SAI-1620m through the correct SICC cable and Safety Manager configuration.
- Does FC-TSHART-1620M support every HART multiplexer?
- No universal compatibility is claimed. The Honeywell reference describes specific MTL and P-epperl+Fuchs multiplexer/cable solutions. Send the installed multiplexer and cable references before ordering.
- Is 1.5 A per channel the usable output rating of FC-TSDO-0824?
- It is the published maximum continuous-current boundary of the FTA. Honeywell explicitly states that the actual maximum current is defined by the connected output module, so both the SDO module and the field load must be checked.
- Can FC-BKM-0001 be removed while Safety Manager is running?
- Honeywell permits placement or removal without interrupting the application program, but removal always clears all forces. The Force Enable switch must be OFF, and the action must follow the site's authorized safety maintenance procedure.
- When should the FC-BKM-0001 batteries be replaced?
- Honeywell recommends every five years and after substantial discharge. Also review the accumulated backup time, battery-switch position and BKM diagnostics rather than relying only on calendar age.
- What information is needed for an accurate quotation?
- Send complete front and side label photos, FC/FS type and version, Safety Manager release, chassis or FTA position, SICC and HART cable references, quantity and destination. For analog loops, include whether transmitters are active or passive.
Send your message to this supplier
People who viewed this also viewed
-
US$123.00 / Piece
-
US$123.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Honeywell
- Honeywell FC-Tpsu-2430 FC-PSU-240516 FC-Tshart-1620m FC-Bkm-0001 FC-Tsdo-0824 FC-Sai-1620 DC/DC Converter Safety Manager System Module
Related Categories
Hot Searches
- Laser Module Factories
- Dc Battery Factories
- Input System Factories
- Electric Power Module Factories
- Dc Input
- Input Output Module
- Voltage Input Module
- Signal Input Module
- Input Communication Module
- FC-Tpsu-2430 DC DC Converter Bulkbuy